Convert a refractometer Brix reading to specific gravity and Plato, and correct your final gravity and ABV once fermentation has started and alcohol is skewing the reading.
A refractometer measures Brix from a couple of drops of wort. Divide the reading by your wort correction factor (WCF, usually 1.02 to 1.06, default 1.04) to get the true sugar content in Plato, then convert to specific gravity. Once fermentation starts, alcohol bends light too, so a plain Brix-to-SG conversion reads too high. The final gravity tool corrects for that with Sean Terrill's cubic formula (2011), which fits hundreds of paired refractometer and hydrometer readings better than the older Bonham and Novotny equations.
Your refractometer read 15.0 Brix before pitching and reads 7.5 Brix a week later. With a WCF of 1.04, the corrected readings are 14.4 and 7.2 Brix. Original gravity is 1.059. A straight conversion of 7.5 Brix would suggest about 1.029, but Terrill's formula gives a corrected final gravity of 1.013, for about 6.0% ABV and 78% apparent attenuation.
Watch for: Refractometers are calibrated with distilled water at about 68 F / 20 C. Zero yours before brew day and let the sample cool on the prism for a few seconds before reading.
Divide the refractometer Brix by the wort correction factor, then use SG = 1 + Brix / (258.6 - (Brix / 258.2 x 227.1)). For example, 12 Brix with no correction is about 1.048 SG, and 12 Brix with a 1.04 correction factor is about 1.046 SG.
Refractometers read sucrose, and wort sugars bend light slightly differently, so most refractometers read 2 to 6 percent high on wort. The wort correction factor (often 1.04) fixes that. Find your own by comparing refractometer and hydrometer readings of the same unfermented wort on several brew days and dividing the refractometer Brix by the hydrometer Plato.
Alcohol has a higher refractive index than water, so once fermentation starts a refractometer overstates the remaining sugar. You need both the original and current Brix readings and a correction formula such as Sean Terrill's to estimate the true final gravity.
Almost. Both express percent sugar by weight and differ only in the third decimal place, so brewers treat them as equal. The difference that matters is the wort correction factor between a refractometer's Brix reading and the true Plato of wort.
Terrill's formula is usually within a few gravity points of a hydrometer for typical beers. Accuracy drops for very high gravity beers, wort with a lot of unfermentable sugars, and when the correction factor is wrong, so confirm with a hydrometer before packaging.